Tripp Lite Extended-Run Single-Phase Battery Cabinet specs
The Tripp Lite Extended-Run Single-Phase Battery Cabinet serves as an essential backup power solution, designed for environments where prolonged uptime is critical.
The Tripp Lite Extended-Run Single-Phase Battery Cabinet serves as an essential backup power solution, designed for environments where prolonged uptime is critical.
The battery cabinet structure is rated up through Seismic Zone 4 applications in compliance with the Uniform Building Code.
Model BC-1825 requires a 240 Vac connection between the UPS and battery cabinet for battery charging. This connection is made from CN14A of the battery cabinet to CN14 of the UPS (and
Need help? Do you have a question about the Extended-Run Single-Phase Battery Cabinet and is the answer not in the manual?
Need help? Do you have a question about the Extended-Run Single-Phase Battery Cabinet and is the answer not in the manual?
It is designed for single phase input and output with a "no-break" transfer between bypass and UPS power. For 5 kvA and 6 kVA models, the UPS shall have the option of a hardwire
The 6k & 10k single phase models have built in isolation transformers that create their own neutral. This allows for the installer to select and wire one of a multitude of output voltage options.
Introduction Tripp Lite''s Extended-Run Single-Phase Battery Cabinets connect to SmartOnline 3-Phase UPS Systems to provide long-lasting battery backup for data centers,
The battery cabinets ship with six-foot long connection cables. Contact Toshiba Customer Support at 1-877-867-8773 if longer cables are required for your application, or if additional cables or
PDF version includes complete article with source references. Suitable for printing and offline reading.
The UPS is contained in one or two rugged steel cabinets. Only the 15 kVA and 20 kVA models have two cabinets, one containing the power electronics and the other containing the batteries and single phase distribution outlets. The UPS and battery cabinets are configured for tower, stack and rack-mount configurations.
The battery charging circuit remains active when in bypass or online states. For 15 kVA and 20 kVA models, the charging system automatically adjusts the maximum charger power, up to 3 kW, based on the installed battery capacity and current through each battery string to avoid excessive charging that could result in blotted batteries.
Charging: Upon restoration of the AC input source, the UPS simultaneously recharges the battery and provides regulated power to the critical load. The intelligent battery management system contains a temperature monitoring circuit and compensation algorithm that regulates the battery charging voltage and current so as to optimize battery life.
Scope: This specification describes the operation and functionality of continuous duty, single-phase input and output power (1:1) and split-phase (two models), solid-state, static Uninterruptible Power Supply model, hereafter referred to as UPSs.